Prolite Plastics recently terminated its activities in the corrosion industry. In order to better serve your needs, AC Plastiques Canada Inc. has acquired the rights to the former Prolite Plastics website, e-mail addresses, and part of their inventory and equipment. Any inquiries to their former email addresses are now automatically redirected to our attention. Please click here to be redirected to our website where you will get more insight into our company. We look forward to serving you in a near future!

PROLITE PLASTICS LTD.
SPECIALTY DUAL LAMINATE HEADERS FOR SODIUM CHLORATE


Description: 18" dia. ECTFE/FRP Header
Contents: NaClO3 at 95°C
Corrosion Liner: 2.3mm ECTFE fabric backed
Structural Resin: Dow Derakane 411 vinyl ester resin
Construction: 3/8" thk. hand lay up pipe

Dual Laminate Headers used in Sodium Chlorate Processes

Prolite Plastics Ltd. has provided specialty fluoropolymer lined FRP headers for many sodium chlorate manufacturers for over 25 years.

Recent testing by the Swedish Corrosion Institude has led to the introduction of ECTFE lined FRP piping for Hydrogen rich gas streams and more recently Ausimont MFA fluoropolymer lined FRP piping for feed brine lines and sodium chlorate collection lines.

In lower temperature applications CPVC and PVC lined FRP piping have provided sufficient corrosion resistance. As processing temperatures increased, different material pipe liners were tried. One of these materials was FEP which was installed as a loose liner. FEP loose liners have continuously failed due to collapse under vacuum conditions and also water vapour permeation of the liner.

The ECTFE and MFA liner materials have proven to be more permeation resistant. Furthermore, with proper bonding techniques to the FRP structural laminate, the liners are sufficient to resist full vacuum. The ECTFE and MFA lined FRP products are also less expensive than exotic metals such as titanium.